Quick Response | 12-bit high-speed AD acquisition, 64 points per cycle, single-chip microcomputer for digital processing, electronic module for fast compensation |
Multiple Adjustment Modes Can Be Set | Synchronization: When synchronization is set, AD simultaneously collects the true effective values of the three-phase voltages A, B, and C for average calculation, and gives instructions for compensation, which can effectively improve the imbalance of the three-phase voltage. |
Separate regulation: When separate regulation is set, the three-phase voltage is adjusted separately to ensure that the three-phase voltage is within the accuracy range, which is particularly suitable for single-phase loads | |
Automatic judgment: The microcomputer automatically analyzes whether to perform synchronization or separation | |
Advanced Measurement Technology | 2-bit AD acquisition, single-chip microcomputer for digital filtering and true effective value calculation |
Precise and Accurate Control | Perfect combination of large-scale programmable logic devices and single-chip microcomputers |
User-friendly Interface | Various indicators (output voltage, voltage regulation accuracy, protection function) can be set through the touch keys of the operation panel |
Output Waveform without Distortion | Contactless zero-crossing switch switching, same frequency, phase lock, sine wave superposition compensation principle |
Resistant to Harmonic Interference | True RMS voltage detection |
Wide Load Range | Resistive, capacitive and inductive loads can be adapted |
Slow Start and Shock Resistance | With the function of voltage stabilization before output |
Full Protection Function | When overvoltage or undervoltage occurs, it can be protected within 1 second or automatically switched to bypass operation without interruption. It also has perfect phase loss, overload, short circuit protection and sound and light alarm function after fault. |
Voltage and Current Display | Voltage and current true effective value digital display |
Input |
Voltage Regulation Range |
Three-phase 304V~456V Simplex 176V-264V |
Frequency |
50HZ~60HZ |
|
Output
|
Rated Voltage |
Phase voltage 220V,Line voltage380V |
Center Voltage Adjustment Range |
±7% |
|
Voltage Stabilization Accuracy |
±(1~5)%Optional(normal setting is ±2%) |
|
Response Time |
≤30 ms |
|
Waveform Distortion |
No additional waveform distortion (static) |
|
Efficiency |
≥98% |
|
Three-phase Unbalance |
Three-phase voltage automatic balancing |
|
Delay Output |
Stabilize voltage first and then output (to protect equipment from shock) |
|
Protection |
Overpressure |
When the output phase voltage exceeds 10% (245V), the output will be cut off or switched to bypass continuously. |
Undervoltage |
When the output phase voltage is lower than 10% (195V), the output will be cut off or switched to bypass continuously. |
|
Phase Loss |
Available (automatic cut-off) |
|
Overload |
Electronic detection, overload cut off output within 3 minutes |
|
Overcurrent |
Electronic detection and circuit breaker dual protection |
|
Short Circuit |
Electronic detection and circuit breaker dual protection |
|
Bypass |
Manual or uninterrupted automatic bypass |
|
Instruction |
Voltage |
A, B, C three phases have true RMS digital |
Current |
A, B, C three phases have true RMS digital |
|
Working Status |
Voltage stabilization state/mains power state |
|
Abnormal |
||
Overvoltage, undervoltage, overload, fuse blown |
||
Way of Working |
It has two working modes: voltage stabilization and mains power supply. |
|
Overload Capacity |
5 times rated current for 1 second |
|
Maintenance Method |
Maintenance-free |
■ Model specifications and installation dimensions
Model |
Rated Capacity(KVA) |
Input Voltage Range (V) |
The Output Voltage(V) |
Rated Output Current (A) |
Cabinet Dimensions (mm) |
weight (kg) |
ZBW-10 |
10 |
Three-phase |
Three-phase |
15 |
500×500×1000 |
140 |
ZBW-20 |
20 |
30 |
500×500×1000 |
160 |
||
ZBW-30 |
30 |
46 |
600×600×1300 |
180 |
||
ZBW-50 |
50 |
76 |
600×600×1300 |
195 |
||
ZBW-75 |
75 |
114 |
660×660×1500 |
316 |
||
ZBW-100 |
100 |
152 |
660×660×1500 |
330 |
||
ZBW-150 |
150 |
228 |
700×700×1600 |
450 |
||
ZBW-225 |
225 |
342 |
900×800×1900 |
530 |
||
ZBW-320 |
320 |
486 |
1100×800×2200 |
630 |
||
ZBW-400 |
400 |
608 |
1100×800×2200 |
750 |
||
ZBW-500 |
500 |
760 |
1200×1000×2200 |
870 |
||
ZBW-600 |
600 |
912 |
1200×1000×2200 |
980 |
||
ZDBW-3 |
3 |
Single-phase |
Single-phase |
14 |
250×500×500 |
20 |
ZDBW-5 |
5 |
23 |
250×500×500 |
30 |
||
ZDBW-10 |
10 |
45 |
350×600×600 |
52 |
||
ZDBW-20 |
20- |
91 |
350×600×600 |
79 |
||
ZDBW-30 |
30 |
136 |
660×660×1400 |
110 |
||
ZDBW-50 |
50 |
227 |
660×660×1400 |
145 |
■ Precautions for Use
This series of voltage stabilizers should be used indoors, and the normal use conditions are: |
■ Remark
1. Three-phase four-wire system, phase voltage 220V±30%, line voltage 380V±30% (please specify when ordering);
2. ZBW series products all use three-phase voltage regulation separately, with three-phase voltage automatic balancing function;